PS Power Controls
PS Power Controls
Ayanavaram, Chennai, Tamil Nadu
SEND SMS
SEND EMAIL

Harmonic Test and Solution - AHF

Prominent & Leading Manufacturer from Chennai, we offer harmonic testing services, energy audit cum harmonic test and harmonic suppression as per cea - tangedco.

Harmonic Testing Services

Approx. Price: Rs 8,000 / Unit

Product Details:

Preferred Audit Locationon
Analytical Service Frequencyon
Application/Usageon

We do conduct Harmonic Testing services to evaluate Harmonic Filter requirements and to avoid the penalty from TNEB. Technical Specification: IEC 61010 CAT IV 600V V & I transients (ALM 33) 1⁄2 cycle Alarms (ALM 33) Multi-tasking 9 Current Clamp options
Request
Callback
Get Best Quote
Yes! I am interested

Energy Audit Cum Harmonic Test

Energy Audit Cum Harmonic Test
  • Energy Audit Cum Harmonic Test
Get Best Quote
Approx. Price: Rs 7,500 / Unit

Product Details:

Reason for AuditPower Factor Improvement
Application/UsageCommercial

Basic measurements offered

· True RMS Values for Voltage, current and frequency

· Variation of kW, kVA during the production cycle

· Actual KVAR requirement that needed to maintain Unity PF at very efficient level even at distributed levels.

· Energy consumption at feeders and loads w.r.t production

· Load on/ off / idling time w.r.t energy consumption

· Demand cross-check at Input

· PF, kVAR study at Inrush currentmeasurement at Incomers starting from 10 ms.

· Evaluation of energy saving devices

· Evaluation of modifications on machinery w.r.t energy consumption

· Distortion PF (PF) and Displacement PF (Cos phi) study

·

Optional: Power Quality Measurements

· Harmonics (Voltage & Current) from 1st to 50th & Total Harmonic distortion (THD) on sensitive machinery and non-linear loads that are generating harmonics

· Evaluation of harmonic filters (if available)

· Voltage and current unbalances

· K factor (If at Transformers)

· Crest factor at sensitive electronic equipment

· Neutral current on neutral cables

· Voltage Sags & Swells

· Waveform pictures & Phasor diagram pictures

· harmonics are generated or received at a particular load (using ALM 35)

· Sequence of harmonics ( +ve, -ve and Zero - using ALM 35)

Request
Callback
Yes! I am interested

Harmonic Suppression As Per Cea - Tangedco

Harmonic Suppression As Per Cea - Tangedco
  • Harmonic Suppression As Per Cea - Tangedco
Get Best Quote
Approx. Price: Rs 8,000 / Unit(s)

Product Details:

BrandEMERSON
ModelAF3
ApplicationIndustrial Use

Harmonic Suppression as per CEA - TANGEDCO


We do have Harmonics analyzer for testing and adequate harmonic suppression equipment ( Active Harmonic Filter and Passive Filters ) to avoid dumping of harmonics beyond the limits ( I thd < 8 % and V thd < 5 % ) as specified by CEA regulations
.

Request
Callback
Yes! I am interested
X
Looking for “Harmonic Test and Solution - AHF”?


Reach Us
HPS Harikrishnan (Head-Sales & Marketing)
3/4, Thirumalai Raja Street, Ayanavaram
Chennai- 600023, Tamil Nadu, India


Call Us

Send E-mail

Send SMS