PS Power Controls
PS Power Controls
Ayanavaram, Chennai, Tamil Nadu
SEND SMS
SEND EMAIL

Harmonic Testing and Mitigation

 

Harmonic Testing

Harmonic Testing
  • Harmonic Testing
Get Best Quote
Approx. Price: Rs 8,000 / UnitGet Latest Price

Product Details:

Preferred Audit LocationOn-Site Testing
Application/UsageIndustrial
Analytical Service FrequencyYearly
Load TypeMotor

  • Harmonics Study as per CEA Rules
  • Today industry is highly conscious of the need for energy management and power quality improvement to save energy costs, reduce failures and improve productivity. To enable such customers who would like to get immediate benefit of measurement at various power flow points at their works. We are now offering PQ Study Services to evaluate the Harmonic Levels are within the CEA Rules ( I thd < 8 % and V thd 5 % ) and offers sophisticated Load Managers (ALM – 35) along with experienced personnel to measure power, energy and power quality parameters and submit a report on the same to help them in maintain the Harmonics level as per the CEA Rules.

Request
Callback
Yes! I am Interested

Energy Audit Cum Harmonic Test

Energy Audit Cum Harmonic Test
  • Energy Audit Cum Harmonic Test
Get Best Quote
Approx. Price: Rs 7,500 / UnitGet Latest Price

Product Details:

Reason for AuditPower Factor Improvement
Audit AreaAC
Application/UsageCommercial

Basic measurements offered

· True RMS Values for Voltage, current and frequency

· Variation of kW, kVA during the production cycle

· Actual KVAR requirement that needed to maintain Unity PF at very efficient level even at distributed levels.

· Energy consumption at feeders and loads w.r.t production

· Load on/ off / idling time w.r.t energy consumption

· Demand cross-check at Input

· PF, kVAR study at Inrush currentmeasurement at Incomers starting from 10 ms.

· Evaluation of energy saving devices

· Evaluation of modifications on machinery w.r.t energy consumption

· Distortion PF (PF) and Displacement PF (Cos phi) study

·

Optional: Power Quality Measurements

· Harmonics (Voltage & Current) from 1st to 50th & Total Harmonic distortion (THD) on sensitive machinery and non-linear loads that are generating harmonics

· Evaluation of harmonic filters (if available)

· Voltage and current unbalances

· K factor (If at Transformers)

· Crest factor at sensitive electronic equipment

· Neutral current on neutral cables

· Voltage Sags & Swells

· Waveform pictures & Phasor diagram pictures

· harmonics are generated or received at a particular load (using ALM 35)

· Sequence of harmonics ( +ve, -ve and Zero - using ALM 35)

Request